REPAIR PARTS FOR BAUMANOMETER® DESK MODEL

ORDERING INFORMATION:

Cat. No.         Description

2136               Leaf spring for lock push plate for Desk Model

2140               Knurled cap complete for Desk Model

2142               Diaphragm filter for Desk Model

2143                Leather cap washer for Desk Model

2145                Silicone rubber tube washer for Desk Model

2150                Complete reservoir and bracket assembly for Desk Model

2154                Bracket screw for Desk Model

2300                Mylar® Clad Cartridge Tube for Desk Model (300 mmHg)

2320                Cover Only for Desk Model

2330                Case Only for Desk Model

2331                Hinge Post, right hand for Desk Model

2332                Hinge Post, left hand for Desk Model

2333                Screw for hinge post for Desk Model

2334                Hinge posts, pair, with screws for Desk Model

2335                Lock push plate for Desk Model

2337                Complete lock for Desk Model

2338                “Z” Spring for cover for Desk Model

2370                Scale only for Desk Model

2430                Bulb holder for Desk Model

REPAIR PARTS FOR NEW STYLE BAUMANOMETER® STANDBY® MODEL

ORDERING INFORMATION:

Cat. No. Non-Latex                         Description

2200                                Mylar® Clad Cartridge Tube for Standby® Model (300 mmHg)

2233NS                          Hinge cap for Standby® Model

2242                                Diaphragm filter for Standby® Model

2243                                Leather cap washer for Standby® Model

2245                                Silicone rubber tube washer for Standby® Model

2250 2250NL                 Complete reservoir for Standby® Model

2270NS                          Scale only for Standby® Model

2271NS 2271NSNL      Complete scale unit (includes scale unit, reservoir, and

calibrated tube – mercury extra) for Standby® Model

2272NS                           Screws for scale (2) for Standby® Model

2290                                Standard base only for Standby® Model

2291                                Extra 3 lb. weight only for Standby® Model

2292                                Tie rod (complete with hex nut, metal washer and wing nut) for Standby® Model

2295NS                           Body only for Standby® Model

2296                                9″ spacer for Standby® Model

2840                                Knurled cap complete for Standby® Model

STANDBY® MODEL ACCESSORIES

2230                               Ball handle for Standby® Model

2231                               Ball Knob for Standby® Model

2240                               4-Wheel base assembly for Standby® Model

2241                               Caster for 4-wheel base with lock washer and cap nut for Standby® Model

2244                               Set of 4 casters (2 ½”) for 2240 for Standby® Model

REPAIR PARTS FOR BAUMANOMETER® WALL UNIT 33

ORDERING INFORMATION:

Cat. No.             Non-Latex                        Description

2145                  Silicone rubber tube washer for Wall Unit 33

2242                 Diaphragm filter for Wall Unit 33

2243                 Leather cap washer for Wall Unit 33

2300                 Mylar® Clad Cartridge Tube for Wall Unit 33 (300 mmHg)

2420                 Inflation system wall basket

(includes mounting screws and anchors) for Wall Unit 33

2421                 Stainless steel clip type holder for inflation system

(includes mounting screws and anchors) for Wall Unit 33

2833                 Top swivel screw for Wall Unit 33

2834                 Bottom swivel washer for Wall Unit 33

2836                 Connector (reservoir-to-Extendex®) for Wall Unit 33

2840                 Knurled cap complete for Wall Unit 33

2850 2850NL   Complete reservoir for Wall Unit 33

2851                 Mounting bracket with 1 top swivel screw

and mounting anchors and screws for Wall Unit 33

2852                 Mounting screws, pair for Wall Unit 33

2853                 Mounting anchors, pair for Wall Unit 33

2854                 Nylon hanging clip for Wall Unit 33

2910 2910NL   Extendex® tubing, with connector

REPAIR PARTS FOR BAUM WALL ANEROID MODEL

ORDERING INFORMATION:

Cat. No.    Non-Latex                   Description

0930                       Baum Wall & Desk Aneroid Manometer Only

1141                      Crystal for Baum Wall & Desk Aneroid

0945                      Bracket for Baum Wall & Desk Aneroid

2852                      Mounting Screws

2853                      Wall Anchors

2910  2910NL      Extendex® tubing, with connector

2904  2904NL     4 inches straight tubing w/connector

REPAIR PARTS FOR BAUM ROLL-BY MODELS

ORDERING INFORMATION:

Cat. No. Non-Latex                          Description

1131                     Roll-By® Replacement Pole

1132                     Roll-By® Small Basket with mounting bracket

1140 1140NL       Roll-By® Manometer Only

1141                     Roll-By® Manometer crystal

1142                     Roll-By® Handle with mounting screws

1145                     Roll-By® Base Weight (2 lbs.)

1146                     Roll-By® 5 wheel base assembly

1147                     Roll-By® Set of five casters

1148                     Roll-By® Single Caster

1149                     Roll-By® Large Basket with mounting bracket

2904 2904NL       4 inches straight tubing w/connector

2910 2910NL       Extendex® tubing, with connector

Testing for Accuracy

TESTING INSTRUMENT ACCURACY

Your goal is to test instrument accuracy, not the process of blood pressure measurement. You will need a Baumanometer® instrument (mercury-gravity standard) and a “Y” connector with an inflation bulb and valve attached (see below for Test Kit ordering information). Connect one leg to the Baumanometer® instrument and the other to the blood pressure instrument to be tested.

Note: Cuffs and Bags are not used when conducting this test.

The Pressure Standard

A Baumanometer® instrument is functioning correctly and should be used as the pressure standard if:

1. The mercury meniscus is at zero with no pressure applied to the instrument.

2. The instrument is in a vertical position. Note: The Standby model is calibrated at a 20º angle

3. The instrument responds promptly to pressure changes.

Any two Baumanometer® instruments, regardless of age, will provide accurate linear pressure readings at every pressure level if they meet the stated criteria for a correctly functioning manometer.

Test Procedure

Check each instrument to be sure that it is at zero. Slowly inflate the

instruments to 250 mmHg and compare the readings. They should be

the same, however a deviation of +/- 3 mmHg is acceptable. Repeat

this procedure at 200 mmHg, 150 mmHg, 100 mmHg, 50 mmHg and 0

mmHg. If the deviation is greater than +/- 3 mmHg at any of these points,

the instrument being tested is inaccurate and needs adjustment or repair.

NOTES ON ANEROID DEVICES

“Remember, the mere fact that the needle points to zero on the dial of the aneroid manometer when the compression cuff is deflated does not

necessarily mean that the instrument is accurate over the entire pressure range.”

Primer Of Clinical Blood Pressure Measurement by George E. Burch, M.D. and Nicholas P. DePasquale, M.D.

“The readings on the dial at different pressures should check with those of a properly constructed and perfectly functioning mercury manometer.

The fact that the pointer indicates zero may be no guarantee of accuracy over the whole pressure range.”

American Heart Association, Recommendations for Human Blood Pressure Determinations by Sphygmomanometers.

Test Kit

Calibration “Y” connector (To use your Baumanometer® instrument as a standard for pressure measurement).

ORDERING INFORMATION:

Cat. No.    Non-Latex                   Description

2940 2940NL Calibration “Y” connector with 1 ft. #2911 or #2911NL tubing on each leg

2941 2941NL Calibration “Y” connector with 1 ft. #2911 or #2911NL tubing on each leg

with #1890 or #1890NL Bulb and Air-Flo® Control Valve

Note: When used with a “Y” connector, any Baumanometer® instrument can be used to check the accuracy of any other blood pressure device.

Lever Lock Insertion Instructions

PURPOSE

To prevent tampering with the cartridge tube release lever and accidental release of mercury.

PROCEDURE

Push lever ‘A’ forward (toward the chrome plated cap ‘B’) and insert lever lock ‘C’ as shown in diagram.

NOTE: Additional lever locks are available free of charge.